Area Scan
Rotoscan Series
Safety Laser Scanners are a cost-effective and flexible protective device alternative for danger zone guarding of large areas in the vicinity of these machines. Switching between any kind of monitoring area is possible with up to a 6.25 radius, according to the application. All configuration data, such as the definition of the zones, the resolution or the response time, is defined with the RS4soft configuration and diagnostics software. Compactness, protective/warning field combination and field changeover are the essential features of Safety Laser Scanners for guarding corridor supply vehicles. The protection area of the traveling direction and speed of the vehicle is adjusted using staggered protective fields and their situation-conditional activation The Safety Laser Scanner also offers very significant advantages for portal processing systems. On one hand the vehicle can be monitored during the movement, while on the other hand, in standstill the Laser Scanner assumes a danger zone guarding of the tools integrated in the portal
- Guarding large danger zones
- Any protective/warning field contours or configurations
- AS-I safety at work and PROFIsafe Laser Scanners
- Automatic configuration with device exchange and intelligent ConfigPlug
Light Curtains
Leuze Light Curtain
With special task requirements in material conveyance, the blanking of individual beams may be required in order to ensure an efficient, continuous process while simultaneously guaranteeing safety. The Compact Plus-B type 4 Safety Light Curtains in accordance with IEC/EN 61496 have been designed with these requirements in mind. They provide blanking functions for blanking any amount of beams and beam areas of varying sizes
- Plug in module with saved device parameters for fast device swapping
- M12 local connection socket
Leuze Light Curtain
Rapid market changes require flexible production line adjustments. This demands long-life safety sensor technology that is versatile in its application. Whether it is hand protection or danger zone and access guarding, the type 4 Safety Light Curtains of the SOLID-4E series provide reliable protection and ensure the highest possible system availability with their robust and interference-immune design. Protected by a warp-resistant profile housing closed on four sides and with their uncomplicated M12 connection system, they withstand even the toughest industrial conditions
- Type 4 self monitoring
- Slender & robust aluminum housing
- Easy function selection
- Several devices can be cascaded
- Fault-free operation of adjacent devices
- Maintenance free
Leuze Light Curtains
The glass cylinder housed in the COMPACT Safety Light Curtain is firmly closed with a lid. Robust cable bushings in the lid safely enclose the cables suitable for explosion-risk areas, which are to be provided by the customer. COMPACT EX1 can be used in industrial applications, however it cannot be used in pits. The device complies as an electrical piece of apparatus of EX device group II, EX category 2. Devices and protective systems must meet special requirements with use in explosion-risk areas.
- Suitable for safety category 4
- Fault-free operation of adjacent devices
- Ignition protection type “d”
- Complies with ATEX Directive 94/9/EC
- Maintenance free
- Temperature class, T6
Safety Valves
Ross Safety Valves
Ross Controls offers some of the most safety critical pneumatic valve applications in manufacturing today, and Ross is there to help make jobs safer for workers, to help protect customer investments in machinery, and to increase productivity. These safety electrical double valves include the DM1 Series, DM2 Series, and the L-O-X Series. The DM Series features double valves with dynamic monitoring & memory, which means memory, monitoring, and airflow control functions are integrated into two identical valve elements. The valves have dirt tolerant, wear compensating poppets designed for quick response and high flow capacity. Ross L-O-X Series valves are energy isolation valves and are generally used as the first valve in a line supplying compressed air to equipment. This series features a large exhaust port for rapid release, special Teflon seals, simple push/pull manual operation, positive action (2 positions only), and a pressure sensing port.
- Control-reliable 3/2 & 5/2 pneumatic valves
- Manual and solenoid L-O-X® valves for energy isolation
- Silencers & reclassifiers
- Pneumatic internally monitored double valves for safety applications
- Pilot operated check valves (single/double channel sensing available)
- Lockout verification accessories
Interlock Devices
Leuze Interlock Devices
The S20 is a Safety Switch without guard interlocking, which can always be used when the dangerous movement has stopped before the entering person can reach the point of operation. This is the case, for example, with machines and systems where the operator is protected from the point of operation with cages/grids or sliding doors, and a process or production interruption is essentially possible and may be required. The S20 series Safety Switches have a housing made of fiberglass-reinforced plastic in accordance with protection rating IP 67. The models equipped with various contact sets enable integration in control circuits up to category 4 in accordance with EN ISO 13849. The swivel deflecting head and numerous actuators enable universal use of this Safety Switch
- Category 4 integration with contact sets
- 5 actuator starting directions
- Protective insulation
- 8 different actuators for different applications
- Self-centering
- Easy mounting
Leuze Interlock Devices
S400 series Safety Hinge Switches are used for position monitoring of hard guards that can rotate (e.g. protective hoods) with a monitoring switch (without guard interlocking) integrated into the hinge. The S400 Safety Hinge Switches unite the Safety Switch and door hinge functions in one component. This Safety Switch is used with machines with small stopping times, depending on the distance to the point of operation. As external actuators are not required with this Switch, it can also be used problem-free in environments with high dust concentration levels or with heavy particle loads. The Switch is extremely compact, but robust at the same time, and therefore predestined for numerous applications. It also boasts a simple switching angle alignment. If, for example, doors are to be moved or aligned later on, realignment is no problem. The covered screws of the S400 Safety Hinge Switch ensure that it is highly tamperproof
- Maximum 180 opening angle
- IP 67 protection rating
- Compact rounded-off construction design
- Switching angle alignment
- Encapsulated internal actuator
- Extremely manipulation safe
Control Relays
Leuze Safety Relays
If Safety Switches or opto-electronic protective devices are used for guarding danger zones, as the standard link the MSI-SR4 Safety Relay establishes the connection to the machine control system. The relay acts as an E-STOP relay or protective door monitor in accordance with EN 954-1 up to category 4 and EN 60204-1, STOP-0. The MSI-SR4 equipment includes the evaluation of input signals using relay or transistor outputs as well as three safety-related switching outputs and a signal output. A wide range of applications can therefore be covered. The short response time of only 10 ms is especially advantageous. A very compact construction of the machines is therefore possible with hand and finger protection in particular. The MSI-SR4 is easy to connect because of the unambiguous assignment of the functions – this guarantees time saving mounting
- LED displays, K1 & K2, supply voltage, automatic start/restart
- 3 release circuits
- Very short response time
- Monitored start/restart button